Knowledgebase
Online Technical Support
Software Upgrades: Please check our latest Download section.
Search Tip: You can increase the accuracy of your searches by using as many keywords as possible. Remove any common words such as "a", "or", "the" as they will be used in the search. Do not use any operands such as +, or quotation marks to enclose phrases.
|
Issue:
The Perle controller has an additional twinax feature card installed.( the card has an ID 41).How is the card configured.
Solution:
The Perle 494E or 594E controller operates in one of two modes
1) Compatible Mode.
2) Enhanced Mode.
The mode of operation is based on the number of feature cards installed in the controller and the type of configuration that is being created.
If the controller has 1 or 2 feature cards (type 41 or 48 ) installed in slots 2 and 4 and the configuration for example is.
SDLC
FRAME RELAY
ETHERNET
TOKEN RING
Any of the above controller configuration can communicate in compatible mode with the AS/400 as a single controller. (one APPC and one Remote Workstation controller)
The second mode is Enhanced mode.
Any controller with two or more feature cards has to be configured in this mode.
If the controller is configured for tcp/ip ,the configuration has to be completed in enhanced mode.
When additional card feature are installed and are being configured,these cards must have unique information.
If the configuration is TCP/IP a unique IP address has to be assigned to the as/400 configuration,and the controllers Local location and control point names must also be unique this is configured under the Sna Network Information.
Slot 2 . . . . . . . . . . . . . . . . . . . . . . [48] Twinaxial Slot 3 . . . . . . . . . . . . . . . . . . . . . . [49] Fast Ethernet Slot 4 . . . . . . . . . . . . . . . . . . . . . . [48] Twinaxial
|
Slot 2 * Twinaxial
AS/400 Connection
TCP/IP
Ethernet
594e IP Address . . . . . . . . . . . . . . . [101.102.100.030] Global Parameters Ethernet Frame Format . . . . . . . . . . . . . Ethernet Type II Network (Subnet) Mask . . . . . . . . . . . . . [255.255.255.000] Default Gateway IP Address . . . . . . . . . . . [101.102.100.001] AnyNet Keep Alive Duration . . . . . . . . . . . . . . . . . [3 ] H1 AS/400 System 1 AS/400 IP Address . . . . . . . . . . . . . [101.102.200.056] |
SNA Network Information
Default Local Network Name . . . . . . . . . . . . . . . . . [APPN ] 594e LU Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E01 ] 594e CP Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E01 ] Default Mode Name . . . . . . . . . . . . . . . . . . . . . [QRMTWSC ] Pressing F6 to return to 594e - Configuration - Slot Selection |
Tab to
Slot 4 * Twinaxial
AS/400 Connection
Ethernet
594e IP Address . . . . . . . . . . . . . . . [101.102.100.032]
Modify Global Parameters. . . . . . . . . . . . No AS/400 IP Address . . . . . . . . . . . . . [101.102.200.056] |
There is no need to modify the Global parameters,the default gateway and subnet mask was previously configured when the first twinax card in slot 2 was done)
AS/400 ip address
The IP address of the Host can remainthe same on each controller card or the configuration can be changed for a connection to an alternate host.)
Once the As/400 connection has been completed F6 to continue
Next select
SNA Network Information
The page 594e - Configuration - SNA Network Information - TCP/IP Ethernet ,this page will be blank until configured
F9 = copy , this option will copy the configuration information from the stored configuration in slot 2., figure below.
Tab to the LU and then the CP name change the name to something unique (i.e) change the C594E01 to C594E02
All other settings will remain the same for connection to the same as/400.
Default Local Network Name . . . . . . . . . . . . . . . . . [APPN ]
594e LU Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E02 ] 594e CP Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E02 ] Default Mode Name . . . . . . . . . . . . . . . . . . . . . [QRMTWSC ] H1 AS/400 System 1 AS/400 LU Name . . . . . . . . . . . . . . . . . . . . . . [PERLE170] 594e Network Name . . . . . . . . . . . . . . . . . . . . [APPN ] Mode Name . . . . . . . . . . . . . . . . . . . . . . . . [QRMTWSC ] Controller Session Initiation . . . . . . . . . . . . . . . . NO Esc=Cancel F1=Help F3=Exit F6=Return F7=Page Up F8=Page Down F9=copy |