Knowledgebase
Online Technical Support
Software Upgrades: Please check our latest Download section.
Search Tip: You can increase the accuracy of your searches by using as many keywords as possible. Remove any common words such as "a", "or", "the" as they will be used in the search. Do not use any operands such as +, or quotation marks to enclose phrases.
|
Issue:
When CTS/RTS flow is used with the TA8, the signals are not working properly.
Cause:
TA8's units after part# 00-036000 had pins 4 (RTS) + 5 (CTS) reversed.
You can only identify them from the production# printed on the box:
part# 1100063-11 Rev 1.2 printed on unit or box
part# 1100063-12 production# 1200091-12 may be printed on box
Solution:
Re-wire the cable with CTS/RTS reversed from the specified pinout diagram.
All currently produced units have corrected this pinout problem.
part# 1100063-13 or higher
production# 1200091-13 or higher
Note: there was a small production run of units that were labeled on the boxes as TA8+. These are equivalent to 1200091-13.