Issue:
What has to be done to the Perle controllers before upgrading the AS/400
Cause:
Twinax devices will not activate beyond the “Vary On Pending” state.
Solution: In versions V4R4 and up of OS/400 IBM has made some modifications to their MPTN (AnyNet) TCP/IP implementation. Using the current Perle controller software levels these changes do not affect the functionality or performance of any Perle controller utilizing the MPTN feature. However, using previous controller software twinax devices will not activate beyond the "Vary On Pending" state. To ensure a smooth transition, all customers using the MPTN feature need to upgrade their Perle controllers to the latest software levels before upgrading to OS/400 . Controller Type Software Version for MPTN under OS/400 V5R 1,V5R2,V5R3 or higher 594e V5.10 or higher 594T V5.10 or higher 494E V3.91 only
Related
Articles:
1.) How to Check the Software version Req 201
1.)
Controller software updates for the 594 and 494 controllers