Issue:
What information is required to config a 394 for sdlc on the host computer
Solution: SWITCHED LINE COMPARISONS
AS/400 LINE PARAMETERS |
SDLC SWITCHED LINE entries (Note: Perle 394 configured for the SDLC option) |
X.21 SWITCHED LINE entries (Note: Perle 394 configured for the X.21 Switched option) |
X.21 SHORT-HOLD MODE LINE (Note: Perle 394 configured for the X.21 Switched option) |
Data Link Role |
*PRI |
*PRI |
*PRI |
Physical Interface |
*V.35 or *RS232V24 |
*X21 |
*X21 |
Connection Type |
*SWTPP |
*SWTPP |
*SHM |
SHM Node Type |
N/A |
N/A |
*T20 |
NRZI Data Encoding |
*NO or *YES. Must match the Perle 394. |
*NO. |
*NO. |
Calling Number |
Host Network Address |
Host Network Address |
Host Network Address |
AS/400 RWS CONTROLLER PARAMETERS |
| ||
Link Type |
*SDLC |
*SDLC |
*SDLC |
Switched Connection |
*YES |
*YES |
*YES |
Short-Hold Mode |
*NO |
*NO |
*YES |
Exchange Identifier (Required) |
05F000xx, xx= Station address. Only Station address must match the Perle 394. |
05F000xx, xx= Station address |
05F000xx, xx= Station address |
Connection Number |
Remote Network Address |
Remote Network Address |
Remote Network Address |
Station Address |
Values range from 01 - FE. Must match the Perle 394. |
Value range from 01 - FE |
Values range from 01 - FE |
Dial Initiation |
*Linktype or *Immed |
*Linktype or *Immed |
*Linktype or *Immed |