Knowledgebase
Online Technical Support
Software Upgrades: Please check our latest Download section.
Search Tip: You can increase the accuracy of your searches by using as many keywords as possible. Remove any common words such as "a", "or", "the" as they will be used in the search. Do not use any operands such as +, or quotation marks to enclose phrases.
|
Issue:
When using Hylafax 4.1.x to send faxes the output is corrupted.
Cause:
When Hylafax creates the device configuration file it comments out the flow control commands.
Solution:
Note: problem has been corrected in Hylafax 4.2.0.
uncomment the Flow control commands from the /etc/hylax/etc/config.ttyPSxx file then restart the Hylafax device.
example class2:
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class2 # use class 2 interface
ModemRate: 19200
ModemFlowControl: xonxoff # default
ModemWaitForConnect: yes # wait for CONNECT on answer
#
#ModemResetCmds: AT&F2 # what you want for a Supra
ModemNoFlowCmd: AT&K # disable flow control cmd
ModemHardFlowCmd: AT&K3 # hardware flow control cmd
ModemSoftFlowCmd: AT&K4 # software flow control cmd
ModemSetupDTRCmd: AT&D3 # DTR off causes modem to reset
ModemSetupDCDCmd: AT&C1 # DCD follows carrier
ModemSetupAACmd: AT+FCLASS=0;+FAA=1 # enable in class 0
example class1:
# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).
#
ModemType: Class1 # use this to supply a hint
ModemRate: 19200 # rate for DCE-DTE communication
ModemFlowControl: xonxoff # XON/XOFF flow control assumed
#
ModemSetupDTRCmd: AT&D2 # setup so DTR drop resets modem
ModemSetupDCDCmd: AT&C1 # setup so DCD follows carrier
We can provide more information about our products or arrange for a price quotation.