Knowledgebase
Online Technical Support
Software Upgrades: Please check our latest Download section.
Search Tip: You can increase the accuracy of your searches by using as many keywords as possible. Remove any common words such as "a", "or", "the" as they will be used in the search. Do not use any operands such as +, or quotation marks to enclose phrases.
|
Issue:
Configuration example for Trueport and IOLAN+ unit.
Solution:
Trueport
must be configured for Lite Mode and "accept connection from device server".
IOLAN+
Port configuration
The Hardware settings and Flow control must match the attached serial device.
Disable the Keys using ^@.
Under the Access options, notice Local access, mode raw, Connection dedicated, the Host IP address of the SCO5 server, and the Remote port number matches the port number specific in the trueport daemon. The Local port number is not used.
Trueport daemon is running on the server IP address 165.154.128.196. The Remote Port must match the Trueport port number as specified above. Note: The Local Port number is not used in this setup.
** Administrator ** PORT SETUP MENU REMOTE-ADMIN
Hardware Flow ctrl Keys
Speed [9600 ] Flow ctrl [Hardware] Hot [^@] Intr [^@]
Parity [None] Input Flow [Enabled ] Quit [^@] Kill [^@]
Bit [8] Output Flow [Enabled ] Del [^@] Sess [^@]
Stop [1 ] Echo [^@]
Break [Disabled] IP Addresses
Monitor DSR [No ] Src [ ] Mask [ ]
Monitor DCD [No ] Dst [ ]
User Options Access
Name [ ] Keepalive [No ] Access [Local ]
Terminal type [undef ] Rlogin/Telnet [Telnet] Authentication [None ]
TERM [ ] Debug options [No ] Mode [Raw ]
Video pages [0] Map CR to CR LF [No ] Connection [Dedicated]
CLI/Menu [Menu] Hex data [No ] Host [165.154.128.196]
Reset Term [No ] Secure [No ] Remote Port [10001]
MOTD [No ] Local Port [10001]
We can provide more information about our products or arrange for a price quotation.
Send an Email Call Us