Issue:
Controller was working and stopped, the 494 or 594 front panel displays message 420302.
Cause:
The default Mode description on the AS/400 was deleted.
Solution:
Create a new mode description
Type CRTMODD
* *
Mode description . . . . . . . . . : QRMTWSC
Class-of-service . . . . . . . . . : #CONNECT
Maximum sessions . . . . . . . . . : 57
Maximum conversations . . . . . . : 57
Locally controlled sessions . . . : 56
Pre-established sessions . . . . . : 0
Maximum inbound pacing value . . . : *CALC
Inbound pacing value . . . . . . . : 7
Outbound pacing value . . . . . . : 7
Maximum length of request unit . . : *CALC
Data compression . . . . . . . . . : *NETATR
Inbound data compression . . . . . : *RLE
Outbound data compression . . . . : *RLE
Session level encryption . . . . . : *NONE
Text . . . . . . . . . . . . . . . :