Issue:
394 Controller will no go active on the host computer and the front LED continues to display error code b3 (or 63).
Cause:
The floppy diskette loaded in the disk drive of the 394 controller has a bad boot sector.
Solution:
The current 394 controller software diskette has a defective sector,which causes the controller not to boot,to return to normal operating mode,locate a backup configured copy of the controller software diskette and re boot the 394 controller.
If you are unable to locate a copy of the controller software,please go to the software downloads create a new system diskette, reboot the controller in configuration mode and reconfigure the new software diskette
Related
Articles:
1.) Creating new controller software disk(s)
1.)
394 software version 6.66G english.