Issue:
594E controller configured for TCP/IP over ethernet,the IP connection comes up immediately,however the SNA sessions can take anywhere form 10-30 minutes to establish a session.
Cause:
The AS/400 network attribute not set correctly.
Solution:
Go to AS/400 command line and do the following
CFGTCP
Select option 12 (Change TCP/IP domain information)
check field ( Host name search priority) field should be set to *LOCAL
this field may have been defaulted to *REMOTE
Article
ID: |
12 |
Published: |
12/26/2002 1:31:53 PM |
Last
Modified: |
1/13/2003 7:35:26 PM |
Keywords: |
slow,594,494,tcp/ip, |
Issue Type: |
Trouble Shooting |
|