Perle 494 and 594 controller TCP and UDP ports (Firewall)

Issue:
Which ports and protocol need to be open in a firewall to allow the Perle 594 or 494 controller to remain up and operational ?

Cause:
APPC over AnyNet requires the usage of Multiprotocol Transport Networking (MPTN). MPTN uses specific UDP and TCP ports for communications.

Solution:

The ports that need to be open in a firewall to allow the Perle controller to remain up and operational are the following:

TCP - source OR destination port 397

UDP - source and destination port 397

ICMP - Echo (ping) from the controller and echo-reply(ping reply) from the AS/400

Note: sessions initiated by the Perle (controller sessions), have a source TCP port of 397 and a destination port of 1024-65,535 and any sessions initiated by the AS/400 (ie. NWS and PRT sessions) will have a source TCP port of 397 and a destination of 1025-65,535. So you need to account for both of these in the firewall entry.

Related Articles:
1.) Controller loses connection due to IP resets.


Article ID:
296
Published:
3/10/2003 11:49:30 AM
Last Modified:
12/6/2004 12:03:38 PM
Issue Type:
FAQ