Issue:
How do I configure the 594e for TCP/IP over ethernet.
Solution:
This document assumes the windows utility has been installed on the computer. Start Programs 594 Utility Program 594e Standalone You will be presented with the standalone window, if this is a first time configuration there is no configuration file to select. Select Launch Standalone.
P-MAIN 594e Utility
Use the arrow keys to select an option, then press Enter.
Network Link Establishment Configuration <=select configuration Bridge Filter Configuration Concurrent Diagnostics Source Route Bridging Status IP Routing Status VPN IPSec Status System Reset Software Download Utilities
_Esc=cancel F1= Help F3=Exit | Fig. 1
From PC2 menu (fig.2) => press the F9= Enhanced mode
PC2 594e - Configuration
Use the arrow keys to move the cursor, then press Enter.
AS/400 Connection Network Information LAN Gateway Keyboard Translation Frame Relay Bridging Save Configuration
When you have completed Configuration make sure that you save the configuration data before exiting the program. Use the "Save Configuration" option to save the data. Esc=Escape F1= Help F3=Exit F9= Enhanced | Fig. 2
from PC2E-A 594E configuration hardware (fig 3) Before attempting to create a controller configuration ,locate the 594E controller looking at the rear of the controller record the cards ID numbers ,enter the card ID number in the slots as they appear. Note: The ID number in slot 1 if fixed and is based on the controller model being configured,if the card id number does not match there is a previous configuration which was completed for a 594T controller,to resolve close the configuration and rename the 594conf.dat .Start the utility again, the configuration will open with the correct ID numbers.
*Note: This configuration was created based on a 594E controller with one twinax card,if the controller you are attempting to configure has multiple twinax feature cards,add the card ID numbers in the appropriate slot positions to match the controller hardware.
PC2E-A 594e - Configuration - Hardware
Fill in the fields, then press F6. Press Enter to verify the data.
Slot 0 . . . . . . . . . . . . . . . . . . . . . . [00] Multisession Slot 1 . . . . . . . . . . . . . . . . . . . . . . [96] Synchronous Slot 2 . . . . . . . . . . . . . . . . . . . . . . [48] Twinaxial Slot 3 . . . . . . . . . . . . . . . . . . . . . . [49] Fast Ethernet Slot 4 . . . . . . . . . . . . . . . . . . . . . . [ ] None Slot 5 . . . . . . . . . . . . . . . . . . . . . . [ ] None Slot 6 . . . . . . . . . . . . . . . . . . . . . . [ ] None Slot 7 . . . . . . . . . . . . . . . . . . . . . . [ ] None |
Fig 3
F6 will take you to the 594- configuration- Slot Selection. The configurator will automatically position the cursor to slot 2. Press Enter to start configuration.(see fig 4)
PC2E-B 594e - Configuration - Slot Selection
Use the arrow keys to select an option, then press Enter.
Slot 0 Multisession Slot 1 Synchronous Slot 2 Twinaxial Slot 3 Fast Ethernet Slot 4 None Slot 5 None Slot 6 None Slot 7 None
Global Parameters
Save Configuration | Fig 4
Controller slot. . . . . . . . . . . . . . . Slot 2
Controller type. . . . . . . . . . . . . . . 48 - Twinaxial Controller
AS/400 Connection (press enter) TCP/IP (select) Ethernet Note: Please check with your Network Administrator for the IP address information. Using the Arrow keys down arrow to the next screen *Note: With multiple twinax feature cards configured in the controller, each feature card requires a unique IP address, if there are for example three twinax feature cards (you must obtain three unique addresses)
Fill in the Fields and press F6 to return when completed. Note: when completing the As/400 system information,once the as/400 Lu name is entered Press Enter to automatically fill in the remaining fields.
594e IP Address . . . . . . . . . . . . . . . [101.102.100.30 ]
Global Parameters Ethernet Frame Format . . . . . . . . . . . . .Ethernet Type II
Network (Subnet) Mask . . . . . . . . . . . . . [255.255.255.0 ] Default Gateway IP Address . . . . . . . . . . . [101.102.100.1 ] AnyNet Keep Alive Duration . . . . . . . . . . . . . . . . . [3 ]
H1 AS/400 System 1 AS/400 IP Address . . . . . . . . . . . . . [101.102.200.56 ] | Fig 5
When the AS/400 information is complete press F6 to continue Select from menu. SNA Network Information Note: check with the AS/400 system operator for the correct SNA information.
Default Local Network Name . . . . . . . . . . . . . . [APPN ] 594e LU Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E01 ] 594e CP Name . . . . . . . . . . . . . . . . . . . . . . . . [C594E01 ] Default Mode Name . . . . . . . . . . . . . . . . . . . . . [QRMTWSC ] Permanent Ethernet Address on card . . . . . . . . . . . . Source of 594e Ethernet Address . . . . . . . . Address typed below
594e Address Format . . . . . . . . . . . Ethernet Address Format 594e Ethernet Address . . . . . . . . . . . . . . . . . 0200[59400003] Logical Connection: Retry Counter . . . . . . . . . . . . . . . . . . . . . . . . .[10 ] Retry Interval . . . . . . . . . . . . . . . . . . . . . . . . . [6 ] Continuous Retry . . . . . . . . . . . . . . . . . . . . . . . . Yes
Serial Number . . . . . . . . . . . . . . . . . . . . . . [00]-[00000] 594e System Password . . . . . . . . . . . . . . . . . . . . [PERLE ] 594e ID Number . . . . . . . . . . . . . . . . . . . . . . . . [* ]
594e Primary host . . . . . . . . . . . . . . . . . . . . . . . [1] | Fig 6
Concurrent Host Attachment . . . . . . . . . . . . . . . . . . . NO Printer Inactivity Timeout . . . . . . . . . . . . . . . . . . . [000] Enable Host Roaming . . . . . . . . . . . . . . . . . . . . . . .NO Host Roaming Connection Retry Time . . . . . . . . . . . . . . . . [5 ]
Synchronize date and time with primary AS/400. . . . . . . . . NO
H1 AS/400 System 1 AS/400 LU Name . . . . . . . . . . . . . . . . . . . . . . [S1029966] AS/400 Network Name. . . . . . . . . . . . . . . . . . . . [APPN ] 594e Network Name . . . . . . . . . . . . . . . . . . . . [APPN ] Mode Name . . . . . . . . . . . . . . . . . . . . . . . . [QRMTWSC ] Controller Session Initiation . . . . . . . . . . . . . . . . NO Controller Session Not Terminated . . . . . . . . . . . . . . NO
| Fig 7 Note: As seen in the configuration screen there are additional fields below the H1 , H2 thru H4 are optional and are only required if additional AS/400 were available for multi host connections.
Press the (F6) key to continue ,return to the Slot selection by pressing (F6) again. with the Arrow keys move to the Save configuration.
PC2E-B 594e - Configuration - Slot Selection
Use the arrow keys to select an option, then press Enter.
Slot 0 Multisession Slot 1 * Synchronous Slot 2 * Twinaxial Slot 3 * Fast Ethernet Slot 4 None Slot 5 None Slot 6 None Slot 7 None
Global Parameters
Save Configuration | Fig 8
To save the configuration data, press Enter.
Save Configuration File
Configuration File Name: [C:\594UP\594CONF.DAT ]
Usage of this Configuration File: Normal Configuration Backup Configuration
Following are current configuration selections:
Communication Protocol . . . . . . . . . . . . . Ethernet LAN Gateway. . . . . . . . . . . . . . . . . . . Not Configured | Fig 9 Note: The configuration file has been saved on the local drive. Change the drive letter and save file to diskette for transfer to the controller. Go back to the configuration file name and change the path as follows: Configuration File Name: [A:\594CONF.DAT]
Take this diskette along with the controller setup diskette to the controller ,boot the controller in configuration mode and transfer the configuration file.