Issue:
The 494 or 594 controller loses connection when the last user signs off the AS/400 sytem. To recover must vary off and on the remote controller on the as/400.
Cause:
When a 594 or 494 controller is connected to the AS/400 and the descriptions are autocreated the as/400 sets the value switched disconnect to *yes which causes the connections to drop after the last User signs off the system.
Solution:
This example contains the suggested configuration for a remote workstation controller.
Display the AS/400 controller description WRKCFGSTS *CTL (remote controller name if known)
To change description do the following:
1) vary off the controller option 2 = varyoff
2) select 8= work with descriptions.
3) next select 2 = change.
4) Tab to field "Switched disconnect " change from *Yes to *No (as shown in example)
Controller description . . . . . . : C594MRMT Option . . . . . . . . . . . . . . : *BASIC Category of controller . . . . *RWS Controller type . . . . . . . . . : 5494 Controller model . . . . . . . . . : 2 Link type . . . . . . . . . . . . : *NONE Online at IPL . . . . . . . . . . : *YES Remote location . . . . . . . . . : C594MC Local location . . . . . . . . . . : PERLE170 Remote network identifier . . . . : APPN Autocreate device . . . . . . . . : *ALL Switched disconnect . . . . . . . : *NO Message queue . . . . . . . . . . : *SYSVAL Current message queue . . . . . . : QSYSOPR Library . . . . . . . . . . . . : QSYS
Article
ID: |
99 |
Published: |
1/29/2003 11:59:23 AM |
Last
Modified: |
11/14/2003 9:28:19 AM |
Keywords: |
099,devices, session lost,blank screen |
Issue Type: |
Trouble Shooting |
|